From 795d8d4451d7ab0e521656c2878378db3b2329e7 Mon Sep 17 00:00:00 2001 From: Silvano Seva Date: Mon, 29 Mar 2021 09:56:43 +0200 Subject: [PATCH] Implemented input voltage measurement on MD-9600 --- platform/targets/MD-9600/platform.c | 6 +++--- 1 file changed, 3 insertions(+), 3 deletions(-) diff --git a/platform/targets/MD-9600/platform.c b/platform/targets/MD-9600/platform.c index 2838ab9e..314df4d4 100644 --- a/platform/targets/MD-9600/platform.c +++ b/platform/targets/MD-9600/platform.c @@ -123,11 +123,11 @@ void platform_terminate() float platform_getVbat() { /* - * Battery voltage is measured through an 1:3 voltage divider and + * Battery voltage is measured through an 1:5.7 voltage divider and * adc1_getMeasurement returns a value in mV. Thus, to have effective - * battery voltage multiply by three and divide by 1000 + * battery voltage multiply by the ratio and divide by 1000 */ - return 0.0f; + return (adc1_getMeasurement(ADC_VBAT_CH)*5.7f)/1000.0f; } float platform_getMicLevel()