Improved conversion law in MD-3x0 and MD-UV3x0 platform_getVolumeLevel().
Rewritten the conversion law from ADC measurement in mV and normalized 0-255 output, adding a linearization if the pseudo-logarithmic output curve of the potentiometer. Signed-off-by: Silvano Seva <silseva@fastwebnet.it>
This commit is contained in:
parent
d7578c4441
commit
dd46a48cd1
|
|
@ -100,15 +100,32 @@ uint8_t platform_getMicLevel()
|
||||||
uint8_t platform_getVolumeLevel()
|
uint8_t platform_getVolumeLevel()
|
||||||
{
|
{
|
||||||
/*
|
/*
|
||||||
* Knob position corresponds to an analog signal in the range 0 - 1600mV,
|
* Volume level corresponds to an analog signal in the range 0 - 1650mV.
|
||||||
* converted to a value in range 0 - 255 using fixed point math: divide by
|
* Potentiometer has pseudo-logarithmic law, well described with two straight
|
||||||
* 1600 and then multiply by 256.
|
* lines with a breakpoint around 270mV.
|
||||||
|
* Output value has range 0 - 255 with breakpoint at 150.
|
||||||
*/
|
*/
|
||||||
uint16_t value = adc1_getMeasurement(ADC_VOL_CH);
|
uint16_t value = adc1_getMeasurement(ADC_VOL_CH);
|
||||||
if(value > 1599) value = 1599;
|
uint32_t output;
|
||||||
uint32_t level = value << 16;
|
|
||||||
level /= 1600;
|
if(value <= 270)
|
||||||
return ((uint8_t) (level >> 8));
|
{
|
||||||
|
// First line: offset zero, slope 0.556
|
||||||
|
output = value;
|
||||||
|
output = (output * 556) / 1000;
|
||||||
|
}
|
||||||
|
else
|
||||||
|
{
|
||||||
|
// Second line: offset 270, slope 0.076
|
||||||
|
output = value - 270;
|
||||||
|
output = (output * 76) / 1000;
|
||||||
|
output += 150;
|
||||||
|
}
|
||||||
|
|
||||||
|
if(output > 255)
|
||||||
|
output = 255;
|
||||||
|
|
||||||
|
return output;
|
||||||
}
|
}
|
||||||
|
|
||||||
int8_t platform_getChSelector()
|
int8_t platform_getChSelector()
|
||||||
|
|
|
||||||
|
|
@ -104,15 +104,35 @@ uint8_t platform_getMicLevel()
|
||||||
uint8_t platform_getVolumeLevel()
|
uint8_t platform_getVolumeLevel()
|
||||||
{
|
{
|
||||||
/*
|
/*
|
||||||
* Knob position corresponds to an analog signal in the range 0 - 1600mV,
|
* Volume level corresponds to an analog signal in the range 20 - 1650mV.
|
||||||
* converted to a value in range 0 - 255 using fixed point math: divide by
|
* Potentiometer has pseudo-logarithmic law, well described with two straight
|
||||||
* 1600 and then multiply by 256.
|
* lines with a breakpoint around 270mV.
|
||||||
|
* Output value has range 0 - 255 with breakpoint at 150.
|
||||||
*/
|
*/
|
||||||
uint16_t value = adc1_getMeasurement(ADC_VOL_CH);
|
uint16_t value = adc1_getMeasurement(ADC_VOL_CH);
|
||||||
if(value > 1599) value = 1599;
|
uint32_t output;
|
||||||
uint32_t level = value << 16;
|
|
||||||
level /= 1600;
|
if(value < 20)
|
||||||
return ((uint8_t) (level >> 8));
|
return 0;
|
||||||
|
|
||||||
|
if(value <= 270)
|
||||||
|
{
|
||||||
|
// First line: offset zero, slope 0.556
|
||||||
|
output = value;
|
||||||
|
output = (output * 556) / 1000;
|
||||||
|
}
|
||||||
|
else
|
||||||
|
{
|
||||||
|
// Second line: offset 270, slope 0.076
|
||||||
|
output = value - 270;
|
||||||
|
output = (output * 76) / 1000;
|
||||||
|
output += 150;
|
||||||
|
}
|
||||||
|
|
||||||
|
if(output > 255)
|
||||||
|
output = 255;
|
||||||
|
|
||||||
|
return output;
|
||||||
}
|
}
|
||||||
|
|
||||||