GD77 and DM-1801 already have an hardware low-pass filter on the battery measurement probe which causes the low battery protection to trigger at boot if the digital low pass filter is also used. Given that the hardware one is good enough for our purposes, the digital filter is now excluded. Provides a fix for #221 |
||
|---|---|---|
| .. | ||