To prepare for future changes, warn users if their config file currently
does not explicitly specify a default seeding policy.
Because there are now potentially multiple warnings generated that all
relate to the configuration file, group these together and adjust the
wording to be more uniform.
Rewrite module declarations that use the `#[path="…"]` annotation
to the more idomatic `pub mod …` + `pub use …` forms.
For the "self" module, that is not possible because `self` is an
identifier in Rust, and also `r#self` is not admissable as a raw
identifier, so stick to `rad_self`.
Files in submodules were patched as appropriate.
If we ever want to disentangle the users' identity from the node, then
the `rad node` commands must learn to print the information related to
the node, so here we go.
As a library crate, it is bad to return such generic errors.
To get there, errors from `inquire` are downcasted.
This allowed to clean up the public interface of `radicle-term`, so that
it does also not leak the `inquire::InquireError` in its public API.
Symbols signaling status of a process and similar are duplicated in
three different crates. Also two different symbols to signal success are
used:
1. ✓ ( Check Mark, U+2713)
2. ✔ (Heavy Check Mark, U+2714)
Work against that by referring to `radicle-term` from the other crates.
Only the latest log was kept as `node.log.old`. Now, log files are
numbered (`node.log.1`, `node.log.2` and so on). Also `node.log` is now
a hard link to the current log file. `rad node stop` will delete
`node.log` (note that `node.log.x` stays intact) and `rad node start`
will delete `node.log` before it creates `node.log.y` in case the node
crashed.
Also, when running in foreground mode, now a log file is created. It
just contains the hint that the node was started in foreground mode,
just to avoid confusion.
The implementation is split into a sans I/O part as `struct LogRotator`,
while the I/O counterpart is captured by `struct LogRotatorFileSystem`.
Pay more attention to when a Node ID is displayed in compact form. As
this was sometimes used to save space, e.g. in `rad node status` in
combination with long node addresses (like .onion names), also implement
a compact format for node addresses and use that instead in some cases.
Progress notifications in spinners keep the short form.
Allow the `rad node connect` command to use only a `NodeId` when connecting.
The `NodeId` is used to connect to known addresses, and will stop at the first
address that is connected to.